Anion Exchange IC Columns | Stainless Steel
Suitable for:

Technical data
Name | Specs (mm) | Function |
SH-AC-1 | 4.6 x 250 | Carbonate system;A basic column,can simultaneously analyze 6 kinds of common anions: Cl-, NO2-, Br-, NO3-, H2PO4- , SO42- |
SH-AC-3 | 4.0 x 250 | Carbonate system;Simultaneously analyzing 7 kinds of common anions: Cl-,NO2-, Br-, NO3-, H2PO4- , SO42- and disinfection by-products of drinking water:ClO2-, BrO3-, ClO3-, DCA , TCA ; certain organic acids such as formic acid, acetic acid, tartaric acid and oxalic acid |
SH-AC-4 | 4.6 x 250 | Carbonate system;Analyzing BrO3- in wheat flour,SO32- and 7 kinds of common anions,as well as some organic acids such as oxalic acid and tartaric acid |
SH-AC-5 | 4.6 x 250 | Hydroxide system;Simultaneously analyzing 7 kinds of common anions and some organic acids such as citric acid.(The negative peaks of water and F- peaks are well separated |
SH-AC-6 | 4.6 x 200 | Carbonate system;A hydrophobic anion column mainly used for anion analysis in nitric acid digestion samples and analyzing samples containing large amounts of NO3- |
SH-AC-7 | 4.0 x 150 | Carbonate system;A rapid analysis column,can simultaneously analyze 6 kinds of common anions: Cl-, NO2-, Br-, NO3-, H2PO4-, SO42- within 6 minutes |
SH-AC-8 | 4.6 x 250 | Carbonate system; A bromate rapid analysis column for analyzing 7 kinds of anions within 12 minutes: Cl-, NO2-, BrO3- wheat flour), Br-, NO -, H2PO4- , SO42- |
SH-AC-9 | 4.6 x 250 | Carbonate system;Simultaneously analyzing 7 kinds of common anions:F-, Cl-, NO2-, Br-, NO3-, H2PO4- , SO42-.The negative peaks of water and F- peaks are well separated |
SH-AC-11 | 4.6 x 250 | Hydroxide system;A bromate analysis column, can simultaneously analyze 7 kinds of common anions and disinfection by-products of drinking water :ClO2-, BrO3-, ClO3-, DCA , TCA |
SH-AC-12B | 3.0 x 250 | Carbonate system;Simultaneously analyzing 7 kinds of common anions and disinfection by-products of drinking water:ClO2-, BrO3-, ClO3-, DCA , TCA.The tailor-made microbore column can save eluent and improve response value |
SH-AC-12A | 3.0 x 250 | Hydroxide system;Simultaneously analyzing 7 kinds of common anions and disinfection by-products of drinking water:ClO2-, BrO3-, ClO3-, DCA , TCA.The tailor-made microbore column can save eluent and improve response value |
SH-AC-14 | 4.6 x 150 | Carbonate / acetic acid system;A special column for S2- and CN- analysis (specially developed for amperometric detector) |
SH-AC-15 | 4.6 x 200 | Hydroxide system; Analyzing azide, nitrate and bromate ion by suppression conductance method |
SH-AC-16 | 4.6 x 250 | Hydroxide system; A special column for polyphosphate analysis |
SH-AC-17 | 4.6 x 250 | Hydroxide system; Analyzing I- by conductance method, can also be used to analyze I-, SCN-, S2O3- |
SH-AC-18 | 4.6 x 250 | Carbonate system;Simultaneously analyzing 7 kinds of common anions: F-, Cl-, NO2-, Br-, NO3-, H2PO4- , SO42- |
SH-AC-19 | 2.1 x 200 | Hydroxide system; With fine diameter, low flow rate, high signal response value,it can simultaneously analyze7 kinds of common anions and BrO3- |
SH-AC-20 | 2.1 x 200 | Carbonate system;With fine diameter, low flow rate, high signal response value,it can simultaneously analyze 7 kinds of common anions and BrO3- |
SH-G-1 | 4.6 x 50 | Universal guard column; Insoluble solid particles in mobile phase and samples can be filtered on-line |