ClarityChrom 8.7 – Educational license
Educational System license for one system
only for educational systems; no autosampler control included; cannot be extended with other modules
ClarityChrom is an easy-to-use Chromatography Data System for workstations. The Educational System license is exclusively bundeled with the AZURA Educational System and features:
- a single instrument license,
- an HPLC control module (no autosampler control), and
- two offline licenses to evaluate data on two additional PCs
The license cannot be upgraded with additional options, as autosampler, PDA, SST or FRC extensions.
Software
Software name | ClarityChrom |
---|---|
System architecture | 32-bit CDS |
Operating system | Windows 10, Windows 8.1, Windows 7, all 32- and 64-bit |
Expandability
Stand-alone | Workstation version, 1 system controlled by one computer, no extensions |
---|---|
Client/server | No Client/Server functionality |
Multi-user environment | Selectable system of user accounts with independently customizable behavior and appearance for individual users |
Network environment | Easy offline data sharing (at the file level) among all stations in a local network |
Fields of application | Analytical HPLC |
Supported instruments | All Knauer devices except autosamplers are supported, driver for devices from many other manufacturers are available |
Instrument connection | Supports RS-232, Ethernet, PCI interface card, A/D-D/A interface |
Recommended PC hardware | Pentium 2 GHz, 4 GB RAM, 80 GB free hard disk space, separate graphics card if one PC should control more than one system, USB for dongle, connectors as LAN, RS-232 etc. for device control |
Graphics capabilities | Multiple chromatogramm view and overlay |
Integration | 27 integration parameters (peak width, threshold, tangent slope ratio etc.) integration parameters programmable in time, automatic re-integration |
Calculation types | with/without calibration (int./ext. standard method) |
Security and GLP | Installation qualification test of the software; FDA 21 CFR Part 11 conformance, validation with virtual detector |
Instrument control | method-based instrument control, Instrument status display and Direct-Control mode, |
Calibration | 6 types of calibration curves, up to 20 levels, reference peaks, groups, unlimited number of standards (peaks), LOD, LOQ |
Chromatogram operations | Overlay view, custom labels and settings, also applying mathematical operations to chromatograms |
Automation | Sequences, automatic launch of selected commands or applications immediately following chromatogram acquisition – Post run, Batch |
Presentation of results | Integrated customizable table of results, columns with userdefined calculation, summary table, and export in text or database format |
Calculations | Custom: 12 predefined mathematical operators, 15 basic and 4 summary functions, special: Kovats indexes for GC, determination of noise/drift, performance calculations |
Data import and export | ASCII, AIA, dBase |