PC 8+ DHS Stirrer – Without Cell – Polymer Electrode

a

Multi parameter microprocessor digital benchtop instrument, with large, backlit color graphic display and a manual and an automatic data logger function. Memory up to 1000 data with date / time according to GLP.

Complete with glass electrode XS Polymer S7, S7/BNC cable, temperature probe NT 55, no cell conductivity, support holders, magnetic stirrer with adjustable speed, buffers coloured, glasses for calibration with stirring bars and power supply.

PC 8+ DHS Stirrer – Without Cell – Polymer Electrode

Key Features

Analog view Yes
Calibration report Yes, printable. For pH parameters also graph report
Cell type 2 poles
DHS compatible Yes
Display Backlight coloured high definition TFT
GLP Yes
GLP calibration Yes
Inputs 2 x BNC – 2 x RCA – banana 4 mm
IP protection IP 54
Memory 1000 data
Multilanguage Eng – Ita – Deu – Esp – Fra – Cze
Output USB – USB type B – RS232
Password Yes, 4 alphanumerical scripts
pH alarm range Yes
Points of calibration Cond 1…4
Points of calibration pH 1…3 auto / 2 user values
Printer connection Yes
Selectable Cell constant 0,1 / 1 / 10
Stability criteria 3 levels
Standard approved Cond 84 µS – 1413 µS – 12,88 mS – 111,8 mS – 1 user value
Standard approved pH USA – NIST – 2 custom values
Timer calibration due Yes

Specifications

Accuracy (Cond)   ± 1 % f.s.  
Accuracy (pH)   ± 0,02  
Accuracy (Salinity)   ± 1 % f.s.  
Accuracy (TDS)   ± 1 % f.s.  
Accuracy (Temperature)   ± 0,2 °C  
Cond measuring range (max.)   200 mS  
Cond measuring range (min.)   0,00 µS  
Cond resolution   0,01 / 0,1 / 1 µS/cm (automatic scale)  
ORP measuring range (max.)   + 2000  
ORP measuring range (min.)   – 2000  
ORP resolution   1 mV  
pH measuring range (max.)   + 16,00  
pH measuring range (min.)   – 2,00  
pH resolution   0,1 / 0,01  
Reference temperature (max.)   + 30 °C  
Reference temperature (min.)   + 15 °C  
Salinity measuring range (max.)   100 ppt  
Salinity measuring range (min.)   0,01 ppm  
TDS Factor   0.40…1.00  
TDS Factor (max)   1.00  
TDS Factor (min)   0.40  
TDS measuring range (max.)   100 g/l  
TDS measuring range (min.)   0.1 mg/l  
Temperature coefficent (max) 10,00 % / °C  
Temperature coefficent (min)   0,00 % / °C  
Temperature compensation   0,0…100,0 °C  
Temperature measuring range (max.) + 110,0 °C  
Temperature measuring range (min.) – 10,0 °C  
Temperature resolution   0,1 °C  
Working temperature (max.)   + 45 °C  
Working temperature (min.)   0 °C  
Scroll to Top