The AUTOPOL® II is designed as a general-purpose automatic polarimeter for budget-focused Pharmaceutical, Contract Laboratories, Food Laboratories, and College Chemistry Laboratories. Great price yet packed with features and Quality! The Autopol® II offers the same standard and optional features as the Autopol® I but allows greater wavelength flexibility with 589nm and 546nm standard wavelengths and optional 365nm, 405nm, 436nm, 578nm, and 633nm available.

 

 

 

Autopol II

Key Features

Standard

  • 0.01° Arc Accuracy.
  • 589nm and 546nm wavelengths. (A total of 2-4 wavelengths may be ordered initially or as needed)
  • Built in thermoprobe for temperature measurement.
  • Windows Embedded for direct connection to the network server and flexible USB Printing.

Optional

  • TempTrol™ Automatic Electronic Heating & Cooling 15° – 40°C ±0.2°
  • 365nm, 405nm, 436nm, 578nm, and 633nm wavelengths. (A total of 2-4 wavelengths may be ordered initially or as needed)
  • AP Accuracy Option: 0.003° Arc Optical Rotation
  • AP Resolution Option: 0.01, 0.001° Arc Selectable.

Specifications

Measuring ModeOptical Rotation Specific Rotation Specific Rotation Plus Concentration User Defined Scale Sugar Degrees °Z(ISS)
Measuring ScaleDegrees Arc Optical Rotation
Resolution0.01° Arc Optical Rotation 0.01% Concentration 0.01 Specific Rotation
Accuracy0.01° Arc Optical Rotation 0.03°Z (ISS) Sugar Degrees
AP Acccuracy OptionResolution: 0.001° Arc Optical Rotation Reproducibility: 0.002° Arc Optical Rotation Accuracy ±0.003° Arc Optical Rotation
AP Resolution OptionAP Selectable Resolution: 0.01, 0.001° Arc
Reproducibility0.01° Arc Optical Rotation
Measuring Range± 89° Arc Optical Rotation ± 999.99° Arc Specific Rotation 0-99.9% Concentration
PrismGlan Thompson Calcite
Optical Wavelengths589nm 546nm Optional Wavelengths 365nm, 405nm, 436nm, 578nm.
Wavelength SelectionTouchscreen Selectable: 2 standard, 4 Optional
21 CFR Part 11 Compliant SoftwareYes with optional PC Software
Temperature ControlBy external water bath (Standard) TempTrol™ Automatic Electronic Heating & Cooling 15° – 40°C ±0.2° (Optional)
Temp. Probe Measurement Range10° – 100°C
Temp. Probe Measurement Accuracy±0.1°C
Measurement Time5 measurements in less than 25 seconds (avg.)
Light SourceTungsten-halogen 6V, 20W, avg. 2,000 hour life
Optional Light SourceLED 20-30 mA 100,000 hr. avg. life
Sample ChamberAccepts sample tubes up to 200mm
Data Storage32 GB Non-removable Compact Flash
Communication Interface3- USB Ports, 1-USB 3.0 2- RS232 serial ports, Ethernet Port for Network Communication
CalibrationAutomatic calibration via touch screen
Operating SystemWindows Embedded
Display8 inch Color, 800 x 600 pixel resolution with 400 nits of brightness.
User InterfaceTouchscreen
Automatic Sensitivity ControlMeasures samples with transmittance as low as 0.01% (up to OD 4.0)
Input Power100 – 240V, 50/60Hz
Operation Dimensions24.3″W x 12.7″H x 17″D, 617mm W x 323mm H x 432mm D
Shipping Dimensions36″W x 19″H x 21″D, 923mm W x 487mm H x 538mm D
Operating Weight42 lbs. (19.05 kg)
Shipping Weight72 lbs. (32.6 kg)
Calendar/Clock FunctionsBattery-backed clock; time and date sent to computer and printer

Optional Modules

Why are high-quality
polarizing prisms important?

Rudolph manufactures its entry-level automatic polarimeter with the same high-quality optics as its more expensive instruments.

While other manufacturers in this price range use Polaroid Plastic Dichroic Sheet Polarizers, Rudolph does not. Instead, Rudolph uses the same high-quality Glan Thompson Calcite Polarizers used in its high-accuracy models.

Because prisms are two of the most critical optical components in the polarimeter. Polaroid prisms are made of a polymeric plastic where the molecules are stretched and oriented in a specific direction so as to linearly polarize light. These types of plastic sheet polarizers are very inexpensive ($50.00 USD) and are vulnerable to heat, warp over time, deteriorate from moisture, and also have greater light absorption than Calcite Polarizers.

In many cases, the plastic polarizers must be replaced in 3- 5 years. Glan Thompson Calcite Polarizers are comprised of a carbon crystalline structure similar to diamond and have excellent light transmission characteristics. The quality of these prisms is so good, Rudolph guarantees its prisms over the life of the sugar polarimeter.

The Rudolph
AutoFillTM

Rudolph Research Analytical developed AutoFillTM, Patent No. 10,101,353, a simple and easy way to allow fast and reliable polarimeter cell loading. Polarimeter sample cells are filled without bubbles, using Rudolph proprietary BubbleInspectTM technology, sample vapors are contained, and cleaning and drying is automated. Manual cell handling, cleaning and loading is eliminated.

Operation is as simple as opening the AutoFillTM lid, pouring in your sample, closing the lid and pressing start. The sample will be advanced into the Polarimeter cell and stopped once full. The cell is now loaded and the measurement will automatically begin after BubbleInspectTM approves the measurement. When the measurement is complete the operator is prompted to open the AutoFillTM chamber and add a solvent. The AutoFillTM lid is closed and the solution is flushed through the cell to waste. Air drying will automatically begin and end. You are now ready for your next measurement.

  • No need to inject samples with syringes. Samples are easily poured in the AutoFillTM sample well.
  • Eliminate contact with acids and bases.
  • Running air dry for the correct amount of time will fully dry the cell.
  • Cleaning is made effortless.
  • A perfect cell load is guaranteed every time with Rudolph’s exclusive Optical Rotation Homogeneity Inspection Solution.
  • Sample is easily poured into the large AutoFillTM well.
  • All wetted parts are made to stand up against the most aggressive samples including 6 Molar HCl.
  • All Materials are Teflon, Peek, and Kalrez®
  • You may choose to clean with a single solvent or a combination of solvents

AutoFillTM Option is now available on the Autopol I, II, and III. Sample Inspect with sample integrity verification is included standard on the Autopol I, II, and III, and BubbleInspectTM Technology is available on the Autopol V Plus and Autopol VI.

Select a
Temperature Solution

1. Temperature Measurement Only

The Autopol I, II, and III come with a Temperature Probe so that sample temperature can be measured, displayed, and printed.

However, if your product requires Temperature control, then we recommend a temperature control solution shown below. For university education and research, starch analysis, invert sugar, flavors, and fragrances temperature control is not required, and temperature measurement is normally sufficient for these applications.

2. Temperature Control With a Water Bath

Rudolph Research Analytical jacketed cells come standard with
quick release fittings which allow cells to be easily removed from
the sample chamber.
Tubing is held in place by rubber gasketing on top of the trough
and the door. Optional stopper (choose “S” after the cell part no.)
for evaporative samples.
Temperature control is obtained through the use of an external water bath and a jacketed cell. This temperature control solution is popular for very high-temperature applications.

3. Patented TempTrol™ Technology Eliminates the Need for a Water Bath. Here’s how the TempTrol™ System works:

TempTrolTM heating and cooling Peltier transfer surface.

TempTrolTM cell with mating heating and cooling transfer surface.

Place the TempTrolTM cell in your TempTrolTM equipped Autopol® sample chamber to measure to within ±0.2°C of the USP, EP, JP or BP specified temperature
(normally 20°C or 25°C
±0.5°C).

Rudolph provides a temperature validation cell with every TempTrolTM system. The temperature validation cell along with an optional NIST traceable thermometer is designed to validate the temperature control performance of the polarimeter and cell
to ±0.2°C.

The Rudolph
FillStationTM

Many users prefer to load cells with samples outside of the Polarimeter. When this fits with your workflow, Rudolph has engineered a tool to assist you, the Rudolph Polarimeter FillStationTM. Designed to sit on your laboratory bench or under your fume hood and assist you in loading your Rudolph Polarimeter cell easily and reliably, the FillStationTM holds the cell at the right angle, so you always fill the cell from bottom to top. Using a syringe, you inject the sample until it begins to appear at the top port. Once filled, the monitoring light will become bright, and you know you have a full cell free of air bubbles that is ready for measurement. Cap, the Top Cell Port, remove the syringe, cap the Lower Port and go!

  • The cell is held at the right angle and filled from the bottom just the way Rudolph cells were designed to be filled. Perfect every time.
  • Filling from the bottom to top moves any air with the potential to cause a bubble up and out of the cell.
  • Once you see the monitoring light go to bright there is no question that the cell is properly filled.
  • Verification of air free sample loading for even inexperienced operators.
  • Helps eliminate contact with acids, bases, or any sample the user does not want to come in contact with.
  • Less experienced operators can learn to reliably fill cells with minimal training.

System Components

No items found
Scroll to Top