Cond 60 Violab – Without Cell

Professional bench conductivity meter with innovative high-definition colour LCD display, with possibility of brightness adjustment. Conductivity, TDS, Salinity measurement with temperature display. Possibility to select the parameters you want to see on the display. The online guide in setup and calibration allows a simple and immediate use of the device. Automatic calibration of conductivity up to 5 points (84; 147; 1413 microS and 12.88; 111 mS) and a user-defined point. Automatic scale change, selectable reference temperature (15… 30 ° C) and selectable cell constant (C = 0.1; 1; 10). Indication with icons of the calibrated values. Measurement stability indicator and possibility to select 3 stability levels. GLP functions: Date and time, display of calibration and setting data calibration deadline. Manual and automatic data logger with the possibility of downloading data to PC via micro-USB. Connection to external printer via RS232 connector. Data-Link software freely downloadable. All operations are constantly monitored and signalled to the operator via the coloured LED above the display and self-diagnosis messages.

Supplied as standard:

Electrode holder stand, conductivity standard, USB cable, power supply and instructions for use.

Instrument with accessories, without cell.

Cond 60 Violab – Without Cell

Key Features

Calibration report Yes, printable
Display   Backlight coloured high definition LCD  
GLP   Yes  
Inputs   BNC – RCA
IP protection   IP 54  
Memory 1000 data  
Output   Micro USB – RS 232  
PC connection   Yes  
Points of calibration Cond   1…4  
Stability filter   3 levels  
Standard approved Cond   84 µS – 147 µS – 1413 µS – 12,88 mS – 111,8 mS – 1 user value  
Timer calibration due   Yes  

Specifications

Accuracy (Cond) ± 2 % f.s.
Accuracy (Temperature) ± 0,5 °C
Cond measuring range (max.) 200 mS
Cond measuring range (min.) 0,00 µS
Cond resolution 0,01
Reference temperature (max.) + 30 °C
Reference temperature (min.) + 15 °C
Salinity measuring range (max.) 100 ppt
Salinity measuring range (min.) 0,1 ppm
TDS Factor (max) 1.00
TDS Factor (min) 0.40
TDS measuring range (max.) 200 g/l
TDS measuring range (min.) 0.1 mg/l
Temperature coefficient (max) 10,00 % / °C
Temperature coefficient (min) 0,00 % / °C
Temperature compensation 0,0…100,0 °C
Temperature measuring range (max.) + 110,0 °C
Temperature measuring range (min.) – 10,0 °C
Temperature resolution 0,1 °C
Working temperature (max.) + 45 °C
Working temperature (min.) 0 °C

 

Supply

Power supply 100 – 240 V / 50 – 60 Hz

 

Dimensions & Weight

Dimension (LxWxH) 160 x 140 x 45 mm
Weight 380 g