Cond 80+ Stirrer – With Cell VPT 80/1

Digital microprocessor bench-top conductivity meter with large backlit color graphic displayresolution 0.01 μS. Automatic and manual calibration with recognition of 4 conductivity standards (84; 1413 μS, 12.88 and 111 mS) from 1 to 4 points with calculation of the different cell constants and a user-defined standard. Quick manual online and PC software downloadable for free.

Complete with conductivity cell VPT 1 Platinum glass with 2 electrodes (C = 1) with built-in temperature probe, electrode holder, external keyboard, magnetic stirrer with adjustable speed, 2 calibration standards and power supply. 

Cond 80+ Stirrer – With Cell VPT 80/1

Key Features

Calibration report  

Yes  

Cell type  

2 poles  

Display  

Backlight coloured high definition LCD  

GLP  

Yes  

Inputs  

BNC – RCA  

IP protection  

IP 54  

Memory  

1000 data  

Multilanguage  

Eng – Ita – Deu – Esp – Fra – Cze  

Online help  

Yes  

Output  

USB – USB type B – RS232  

Password  

Yes, 4 alphanumerical scripts  

PC connection  

Yes  

Points of calibration Cond  

1…4  

Printer connection  

Yes  

Selectable Cell constant  

0,1 / 1 / 10  

Standard approved Cond

84 µS – 1413 µS – 12,88 mS – 111,8 mS / 1 user value  

Stirring speed control  

Stirrer with indipendent control  

Timer calibration due  

Yes  

Ultrapure water compensation  

Yes  

 

Specifications

Accuracy (Cond)   ± 1 % f.s.  
Accuracy (Resistivity)   ± 1 % f.s.  
Accuracy (Salinity)   ± 1 % f.s.  
Accuracy (TDS)   ± 1 % f.s.  
Accuracy (Temperature)   ± 0,2 °C  
Cond measuring range (max.)   1000 mS  
Cond measuring range (min.)   0,00 µS  
Cond resolution   0,01 / 0,1 / 1 µS/cm (automatic scale)  
Reference temperature (max.)   + 30 °C  
Reference temperature (min.)   + 15 °C  
Resistivity measuring range (max.)   10,00 MOhm*cm  
Resistivity measuring range (min.)   1,00 Ohm*cm  
Salinity measuring range (max.)   100 ppt  
Salinity measuring range (min.)   0,01 ppm  
TDS Factor (max)   1.00  
TDS Factor (min)   0.40  
TDS measuring range (max.)   500 g/l  
TDS measuring range (min.)   0.1 mg/l  
Temperature coefficent (max)   10,00 % / °C  
Temperature coefficent (min)   0,00 % / °C  
Temperature compensation   0,0…100,0 °C  
Temperature measuring range (max.)   + 120,0 °C  
Temperature measuring range (min.)   – 20,0 °C  
Temperature resolution   0,1  
Working temperature (max.)   + 45 °C  
Working temperature (min.)   0 °C  

Supply

Power supply 100 – 240 V / 50 – 60 Hz

 

Dimensions & Weight

Dimension (LxWxH) 162 x 185 x 56 mm
Weight

709 g

+M55

Scroll to Top