Ion Chromatograph | CIC D-100  

 

The ion chromatograph CIC-D100 is a classic product from SHINE, which has proven itself with many customers. Based on the latest user requirements, a new improved CIC-D100 has been developed for conventional detection. The new IC can not only detect anions, cations and other polar substances in different matrix samples, but also separate ions with a difference of 4 orders of magnitude and is more accurate and reliable compared to the previous model. A key switch and intelligent maintenance functions make it even more user-friendly. The instrument is suitable for independent testing institutes, enterprises, environmental protection, chemical industry, mining and metallurgy and other fields.

 

CIC-D100 Ion Chromatograph

Key Features

  • Auto-range conductivity detector
  • It can directly detect the signal from ppb to ppm concentration directly without setting the range
  • Eluent preheating
  • The temperature of the eluent entering the column is kept constant to ensure the stability of the data
  • Intelligent switch
  • Click only once to complete the startup parameter setting and shutdown operation;
  • Multiple detectors available
  • Standard: Conductivity detector
  • Optional: Ampere, UV, mass spectrometer, and other detectors.

Specifications

Pump
Maximum Pressure 42MPa(Stainless steel)
Flow Rate Range 0.001 – 9.999mL/min

 

Column Heater
Operating Temperature Range 20 – 60℃
Temperature Accuracy ±1℃
Temperature Stability ≤0.05℃/h

 

Injector
Maximum Pressure 35MPa
External Diameter of The Tube 1/16″

 

Conductivity Detector
Cell Volume ≤0.8μL
Detection Range 0 – 35000μS/cm
Baseline Noise ≤0.001μS/cm
Baseline Drift ≤0.02μS
Temperature Range 5 – 60℃
Maximum Pressure 10.0MPa

 

Power Requirements 150W
Dimensions(L x W x H) (mm) 310 x 430 x 530
Net Weight(Kg) 22
Gross Weight(Kg) 29

System Components

Eluent Generator

Eluent Generator

Generating the required concentration of eluent online only by adding pure water
Amperometric Detector

Amperometric Detector

Reliable detection of ions with low dissociation rate
Suppressor

Suppressor

Advanced continuous regenerative membrane - electric suppression technology
Cation-Exchange IC Columns

Cation-Exchange IC Columns

IC columns with high reproducibility and separation effect at any time
Anion-Exchange IC Columns (PEEK)

Anion-Exchange IC Columns (PEEK)

IC columns with high reproducibility and separation effect at any time
Anion-Exchange IC Columns (SS)

Anion-Exchange IC Columns (SS)

IC columns with high reproducibility and separation effect at any time
Scroll to Top