Isocratic FPLC System for Size Exclusion Chromatography (SEC)

for up to 10 mL/min

The AZURA® Bio compact SEC system takes care of time-intensive SEC methods in your lab without blocking your fully-equipped FPLC system. Thanks to its compact design and intuitive FPLC software PurityChrom®, the system offers outstanding performance and ease of use. Pre-designed methods are included in the software and can be easily adapted by changing the column volume. AZURA Compact SEC supports all columns available on the market. The AZURA series is modular and can be flexibly configured or supplemented with further modules, e.g. for injection using a sample pump.

Isocratic FPLC System for Size Exclusion Chromatography (SEC)

Key Features

  • Flow rate: 0.001–10 ml/min; 0.1 – 8.0 ml/min (recommended)
  • Maximum system pressure: 50 bar (5.0 MPa)
  • Injection valve for sample injection via sample loop
  • Variable single wavelength UV detector (190–500 nm)
  • Fraction collector for fractionation
  • Compatible with columns from all vendors
  • Intuitive PurityChrom® software
  • System suitable for cold room usage
  • Easily upgradeable to automatic sampling system

Specifications

Purification simple, routine
Application size-exclusion chromatography
Gradient No
Flow rate 10 ml/min

 

System Components

Conductivity monitor with flow cell for up to 100 ml/min and optional pH measurement

Conductivity monitor with flow cell for up to 100 ml/min and optional pH measurement

AZURA CM 2.1S with flow cell - up to 100 ml/min - conductivity monitor with optional pH measurement
Detector type: Conductivity monitor
Measurement range, Conductivity: 0.1 - 999 mS/cm
pH: 0 - 14
Linearity, Conductivity: ± 1 % full scale value (0.1 - 300 mS/cm), ± 1 % full scale value (300 - 999 mS/cm)
Pulse Damper, High Volume, PEEK

Pulse Damper, High Volume, PEEK

KNAUER Pulse Damper, 290 µl, PEEK, 1/16'', 225 bar
Multi-injection valve, biocompatible

Multi-injection valve, biocompatible

Especially for FPLC customers: New biocompatible multi-injection valve for more sophisticated separation tasks. (PEEK, 1/16", 240 bar, 0.75 mm bore size)
Operated: electrical by VU 4.1
Port number: 8
Positions: Multiposition
Material: Biocompatible
Capillary connection: 1/16"
Fraction Collector Foxy R1

Fraction Collector Foxy R1

Fraction collector Foxy® R1 for 1/16“ or 1/8“ tubing
Max. flow rate: 25 ml/min or 125 ml/min
Capillary connection: 1/16'' or 1/8''
Brand: Foxy R1
Rack for Foxy R1/R2

Rack for Foxy R1/R2

Rack for 72 Falcons 15 ml for Foxy® R1/R2
PurityChrom® Basic

PurityChrom® Basic

Basic License for one system
Software name: PurityChrom® 5
Backpressure Regulator

Backpressure Regulator

Backpressure Regulator for 1/16“ OD tubing, 10-32 threads, PEEK, Range 1-20 bar (15-300 psi)
Semi-preparative 3 mm UV Flow Cell

Semi-preparative 3 mm UV Flow Cell

3 mm path length, 2 µl, 1/16", stainless steel, classical KNAUER flow cell
Flow cell type: Semi-preparative UV flow cell
Path length: 3 mm
Capillary connection: 1/16''
Max. flow rate: 50 ml/min
Flow cell volume: 2 µl
Classical Start-Up Kit for analytical HPLC systems with 1/16″ connections, contains precut capillaries

Classical Start-Up Kit for analytical HPLC systems with 1/16″ connections, contains precut capillaries

AZURA® start-up kit 1/16" stainless steel, 0.25 mm ID precut capillaries
AZURA Eluent tray E 2.1L

AZURA Eluent tray E 2.1L

AZURA® Eluent tray E 2.1L for AZURA® devices with a capacity of 6 x 1 l bottles or 4 x 2.5 l bottles or 2 x 5 l bottles, (delivery without bottles)